Search results for "Grid-connected photovoltaic system"

showing 4 items of 4 documents

Effects of the Italian financial crisis on the photovoltaic dissemination in a southern city

2013

Abstract The aim of this paper is to estimate how the profitability of grid-connected PV (photovoltaic) systems may vary month by month due to the changes in all parameters involved in the economic evaluation (discount rate, PV electricity selling price, inflation rate, price of PV devices etc.). The effects of these variations were investigated for a district of a city in the South Italy (Palermo). The results of the analysis provided the trend of the actual coverage of the district power demand from June 2010 to August 2012. In particular the load match index, which considers the daily energy demand covered by PV systems, ranged from almost 30% to less than 12%, which is less than the val…

Consumption (economics)Settore ING-IND/11 - Fisica Tecnica AmbientaleIndex (economics)Photovoltaic Grid-connected photovoltaic systems Financial crisis Economic parametersbusiness.industryMechanical EngineeringPhotovoltaic systemBuilding and ConstructionSolar energyPollutionIndustrial and Manufacturing EngineeringAgricultural economicsRenewable energyGeneral EnergyEconomyEconomic evaluationEnvironmental sciencemedia_common.cataloged_instanceProfitability indexElectrical and Electronic EngineeringEuropean unionbusinessCivil and Structural Engineeringmedia_commonEnergy
researchProduct

Load mismatch of grid-connected photovoltaic systems: Review of the effects and analysis in an urban context

2013

Abstract The mismatch between generated and consumed electricity is a relevant topic of the energy and economic assessment of photovoltaic (PV) systems. Due to the load mismatch some amount of PV electricity may be exported to the grid because the electrical demand is temporarily lower than production, whereas a consumption, which is higher than production and/or that does not match the available PV generation, will require to be supplemented by the public grid electricity. The presence of the load mismatch can cause the effect of disadvantageously purchasing electricity from the grid and/or squandering the unexploited PV energy. If only a very small part of the PV generation is used to sup…

Grid-connected photovoltaic systemEngineeringSettore ING-IND/11 - Fisica Tecnica AmbientaleRenewable Energy Sustainability and the Environmentbusiness.industryPhotovoltaic systemElectrical engineeringEnvironmental economicsGridPurchasingGrid parityStand-alone power systemIncentiveMismatchLoad mismatchGrid-connected photovoltaic power systemElectricitybusinessPhotovoltaic
researchProduct

Theoretical and Experimental Comparison of Total Harmonic Distortion Factors for the Evaluation of Harmonic and Interharmonic Pollution of Grid-Conne…

2006

Grid connected photovoltaic systems are increasingly used in electrical distribution systems. However, they inject distorted currents. Therefore special attention must be paid to harmonic and interharmonic measurements. The new edition of IEC 61000-4-7 introduces the concept of harmonic and interharmonic groups, which implies new expressions for Total Harmonic Distortion factors. In the paper a theoretical and experimental comparison is made between the different total harmonic distortion factors in order to show which of the currently defined distortion factors is best-suited to detect harmonic and interharmonic pollution. Experimental tests were carried out first by means of a calibrator …

Total harmonic distortionEngineeringbusiness.industryPhotovoltaic systemElectrical engineeringEnergy Engineering and Power TechnologyGridlaw.inventionHarmonic analysislawElectrical networkDistortionPersonal computerElectronic engineeringHarmonicElectrical and Electronic EngineeringbusinessGrid-connected photovoltaic systems harmonic and interharmonic analysis IEC 61000-4-7 Ed 2002.IEEE Transactions on Power Delivery
researchProduct

Assessment of Energy and Economic Effectiveness of Photovoltaic Systems Operating in a Dense Urban Context

2013

A methodology that permits testing the level of integration of the photovoltaic technology in urban areas is presented. The percentage of coverage of the electricity demand of grid-connected photovoltaic systems installed on the roofs of buildings were investigated in a district of the city of Palermo (Sicily). After classifying roofs according to their shape, orientation and pitch by means of satellite images provided by Google Earth, the ratio of the productivity of the PV systems and the consumption of electricity of the households was analysed. The results of the energy assessment have been screened considering the economic feasibility of grid-connected photovoltaic systems: the energy …

Urban ContextEngineeringArchitectural engineeringGrid-connected photovoltaic systems Photovoltaic Solar potential urban context Available roof surface Energy assessment Economic assessment Energy cover factorGrid-connected Photovoltaic Systems;Photovoltaic;Solar Potential;Urban Context;Available Roof Surface;Energy Assessment;Economic Assessment;Energy Cover FactorSolar PotentialAvailable Roof SurfaceEnergy Engineering and Power TechnologyContext (language use)Environmental Science (miscellaneous)lcsh:Technologylcsh:HD72-88lcsh:Economic growth development planningPhotovoltaicsEnergy AssessmentRooftop photovoltaic power stationEnergy Cover FactorWater Science and TechnologySettore ING-IND/11 - Fisica Tecnica AmbientaleRenewable Energy Sustainability and the Environmentbusiness.industrylcsh:TPhotovoltaic systemPhotovoltaic mounting systemSolar potentialEconomic AssessmentEnergy assessmentbusinessGrid-connected Photovoltaic SystemsPannelli fotovoltaici conto energia analisi energetica ed economicaPhotovoltaicEnergy (signal processing)Journal of Sustainable Development of Energy, Water and Environment Systems
researchProduct